🔊 Beeper Alert

Sound an audible alarm on your MikroTik device when the internet connection goes down. This script uses the built-in beeper to emit a series of alert tones at different frequencies, providing immediate physical notification that WAN connectivity is lost. Perfect for unattended server rooms, data centers, or remote installations where visual monitoring is impossible. Combines with NetWatch for automated failover detection.

info

Compatible devices:

  • HEX GR3, HEX S - Compact Ethernet routers with built-in beeper
  • HEX PoE - PoE-enabled variant
  • RB3011UiAS-RM - Rack mount 10-port router
  • RB1100AHx4 - 1U rack mount with dual CPU
  • Any RouterOS device with audio output capability

Alert pattern: 10 repetitions of 600Hz (100ms) + 1000Hz (100ms) tones = ~8 seconds total alert

Prerequisites

  • ✅ MikroTik RouterOS device with audio output/beeper (HEX series, RB series)
  • ✅ Access to RouterOS console (SSH, WebFig, or WinBox)
  • ✅ Physical location with audible range (server room, office, etc.)
  • ✅ Internet connectivity detection method (NetWatch, script, or failover trigger)
  • ✅ RouterOS v6.41+ for reliable beeper operation
  • ✅ Optional: Speakers connected to audio jack (for amplified alerts)
warning

Device compatibility: Not all MikroTik devices have speakers. Check your device specs:

  • ✅ Has beeper: HEX, HEX S, HEX PoE, RB-series rack mounts
  • ❌ No beeper: Cloud Router Switch (CRS), Virtual Machine RouterOS, SwitchOS devices

Configuration Steps

Option A: Terminal Configuration (NetWatch Trigger)

  1. Access the terminal via SSH, console, or WebFig terminal

    ssh admin@your-router-ip
  2. Verify beeper is available:

    :beep frequency=1000 length=100ms

    You should hear a 1000 Hz tone for 100ms. If not, device may not have beeper.

  3. Create NetWatch entry for internet detection (ping external DNS):

    /tool netwatch add host=8.8.8.8 interval=10s down-script={
    :log error "> INTERNET DOWN!";
    :for i from=1 to=10 do={
    :beep frequency=600 length=100ms;
    :delay 500ms;
    :beep frequency=1000 length=100ms;
    :delay 300ms;
    }
    }
    tip

    Customize monitoring:

    • Change host=8.8.8.8 to your ISP gateway or reliable external IP
    • Adjust interval=10s for faster/slower detection (faster = more CPU)
    • Replace 8.8.8.8 with local gateway if internet monitored via PPP/WAN
  4. Verify NetWatch was created:

    /tool netwatch print

    Should show entry monitoring 8.8.8.8 with down-script.

Option B: WebFig Configuration (NetWatch Trigger)

  1. Navigate to Tools > NetWatch:

    • Click + to add new entry
  2. Configure NetWatch:

    • Host: 8.8.8.8
    • Interval: 10s
  3. Down Script Tab:

    • Paste the alert script:
    :log error "> INTERNET DOWN!";
    :for i from=1 to=10 do={
    :beep frequency=600 length=100ms;
    :delay 500ms;
    :beep frequency=1000 length=100ms;
    :delay 300ms;
    }
  4. Click OK/Apply

Option C: Manual Script Execution (Testing)

  1. Create a script for manual testing:

    /system script add name="beep-alert" source={
    :log error "> INTERNET DOWN!";
    :for i from=1 to=10 do={
    :beep frequency=600 length=100ms;
    :delay 500ms;
    :beep frequency=1000 length=100ms;
    :delay 300ms;
    }
    }
  2. Run the script manually to test beeper:

    /system script run beep-alert

    Should hear: low tone (600Hz) → pause → high tone (1000Hz) → repeat 10 times

Understanding the Script

Beeper Command Syntax

:beep frequency=FREQ length=DURATION;
ParameterRangeDefaultPurpose
frequency20-20000 Hz1000 HzTone pitch (lower = deeper, higher = shriller)
length1-5000 ms100 msDuration of single beep

Audio Frequency Reference

FrequencySoundUse Case
200-300 HzVery low, bassSubdued alerts, background warnings
600 HzMedium-low, warningFirst tone in dual-frequency alert
1000 HzMid, standardCommon alert tone, easily heard
2000-4000 HzHigh, piercingEmergency alerts, hard to ignore
8000+ HzVery high, shrillCritical alarms, painful if too loud

Script Logic Breakdown

:log error "> INTERNET DOWN!";  # Log event for audit trail

:for i from=1 to=10 do={ # Loop 10 times (10 repetitions)
:beep frequency=600 length=100ms; # Low tone (100ms)
:delay 500ms; # Wait 500ms
:beep frequency=1000 length=100ms; # High tone (100ms)
:delay 300ms; # Wait 300ms
}
# Total time: ~8 seconds (10 × (100+500+100+300)ms)

Timing Details

Iteration 1:
├─ 600Hz beep: 100ms
├─ Delay: 500ms
├─ 1000Hz beep: 100ms
└─ Delay: 300ms
= 1000ms per iteration × 10 iterations = 10 seconds total

But with processing: ~8-10 seconds actual

Verification

  1. Confirm beeper hardware exists:

    :beep frequency=440 length=200ms

    Test tone (should hear A note, 440 Hz).

  2. Verify NetWatch monitor is active:

    /tool netwatch print

    Should show monitoring entry with correct down-script.

  3. Check NetWatch status:

    /tool netwatch print status

    Should show current host status (up/down) and last check time.

  4. Test down-script manually:

    /tool netwatch run [find host=8.8.8.8]

    Should trigger alert if 8.8.8.8 is unreachable.

  5. Simulate internet down (firewall block):

    /ip firewall filter add action=drop chain=forward dst-address=8.8.8.8 protocol=icmp

    Wait for NetWatch interval → should hear alert Remove filter to restore: /ip firewall filter remove [find dst-address=8.8.8.8]

  6. Check system logs:

    /log print where topics~"system"

    Should show INTERNET DOWN! entries when alerts triggered.

  7. Monitor beeper resource usage:

    /system resource print

    Beeper uses minimal CPU (~1% during alert).

Troubleshooting

IssueCauseSolution
No sound when beeper runsDevice has no beeperCheck device specs (HEX/RB-series only); try external speaker
Beeper command not recognizedRouterOS version too oldUpgrade to v6.41+; check /system package print
Very quiet/inaudibleFrequency too low or too highTest range: 800-2000 Hz; try higher values (3000-4000 Hz)
NetWatch doesn't trigger alertWrong host or script not attachedVerify: host is reachable; down-script is present in print detail
Alert stops after first occurrenceNetWatch state doesn't changeInternet must come back UP then go DOWN again to re-trigger
Multiple alerts overlappingNetWatch interval too short + slow recoveryIncrease interval to 30s or higher; add delay before script
Beeper sounds permanentlyScript loop running indefinitelyCheck for syntax errors; limit loop count; add timeout
Script errors: "unknown identifier"Variable name typo or syntax errorVerify: :for, :beep, :delay syntax is exact; no missing colons

Advanced Options

Single loud beep (critical alert):

:beep frequency=4000 length=500ms;
:delay 200ms;
:beep frequency=4000 length=500ms;

Siren-like sound (frequency sweep):

:beep frequency=1000 length=100ms;
:delay 100ms;
:beep frequency=1500 length=100ms;
:delay 100ms;
:beep frequency=2000 length=100ms;
:delay 100ms;
:beep frequency=1500 length=100ms;
:delay 100ms;
:beep frequency=1000 length=100ms;

Continuous alert until manual stop:

:local continue 1;
:while ($continue = 1) do={
:beep frequency=800 length=50ms;
:delay 200ms;
:beep frequency=1200 length=50ms;
:delay 200ms;
}
# Note: Requires manual script termination via `/system script job remove`

Different alert patterns for different failures:

Internet down (3 long beeps):

:for i from=1 to=3 do={
:beep frequency=1000 length=300ms;
:delay 400ms;
}

High CPU alert (rapid beeps):

:for i from=1 to=20 do={
:beep frequency=600 length=50ms;
:delay 100ms;
}

Low memory alert (warbling):

:beep frequency=700 length=100ms;
:delay 150ms;
:beep frequency=1000 length=100ms;
:delay 150ms;
:beep frequency=700 length=100ms;
:delay 150ms;
:beep frequency=1000 length=100ms;

Alert with email notification:

Combine with Send Logs to Email:

:log error "> INTERNET DOWN - Triggering alerts";
:for i from=1 to=10 do={
:beep frequency=600 length=100ms;
:delay 500ms;
:beep frequency=1000 length=100ms;
:delay 300ms;
}
# Email notification sent separately via email backup script

Escalating alert (faster beeps as time progresses):

:for i from=1 to=10 do={
:beep frequency=1000 length=100ms;
:delay ($i * 100ms); # Delays decrease as loop continues
}

Alert with syslog integration:

:log error "CRITICAL: Internet Down - Beeper Alert Triggered";
/log print where message~"CRITICAL" | /tool fetch url="http://syslog-server:514" keep-result=no;

Time-based alerts (disable during maintenance windows):

:local hour [/system clock get hour];
:if ($hour < 2 || $hour > 4) do={
# Only alert outside 2-4 AM maintenance window
:beep frequency=1000 length=200ms;
}

Physical Considerations

Audio Output Methods

  1. Built-in Beeper (HEX, RB series)

    • Limited volume (~60-75 dB)
    • Directional sound
    • No external equipment needed
  2. External Speaker (via audio jack)

    • Better volume control
    • Amplification possible
    • More professional setup
  3. USB Speaker (if supported by RouterOS)

    • Portable
    • Variable volume
    • Not standard on RouterOS

Placement Recommendations

  • Server room: Mount on front rack panel for audibility
  • Office: Place on wall near entrance for dual-purpose monitoring
  • Unattended sites: Use external amplified speaker pointed toward building entrance
  • 24/7 NOC: Integrate with call-out system (combine beeper with Telegram alerts from NetWatch Telegram Alerts)

Device Compatibility Matrix

DeviceBeeperAudio JackNotes
HEX GR3✅ Yes-Compact, built-in beeper
HEX S✅ Yes-Smaller variant
HEX PoE✅ Yes-PoE-powered edition
RB3011UiAS-RM✅ Yes-10-port rack mount
RB1100AHx4✅ Yes-1U dual-CPU rack mount
CRS Series❌ No-Cloud Router Switch (no beeper)
CHR❌ No-Cloud Hosted Router (no audio)
RB750❌ No-Budget router (no audio output)

Completion

Internet down beeper alert is now active!

Next steps:

  • Test beeper hardware: :beep frequency=1000 length=200ms
  • Configure NetWatch to monitor WAN uplink
  • Simulate internet down to verify alert triggers
  • Document alert sound pattern for team
  • Consider external speaker for better audibility
  • Combine with Telegram alerts from NetWatch Telegram Alerts
  • Back up configuration: /system backup save
  • Test monthly to ensure beeper still functions